noris network datacenter.de HOF1
noris network datacenter.de HOF1 is an operational data center operated by noris network in Hof, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | noris network |
| Networks | 1 networks PeeringDB. |
| Also known as | noris network AG Rechenzentrum Hof |
| Address | Graf-Stauffenberg-Straße 6 |
| Coordinates | 50.31767, 11.89697 |
| Website | noris.de |
Power and grid
| Nearest high-voltage substation | Umspannwerk Hof West, 110 kV, 2.1 km away (E.ON Netz GmbH) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Mechlenreuth, 380 kV, 16.1 km away |
| HV substations within 10 km | 6 |
| Power plants within 50 km | 714 MW in 18 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 7.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.8 °C (2001 to 2025) |
| Cooling degree days | 97 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 6 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is noris network datacenter.de HOF1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Hof West (110 kV), about 2.1 km away.
How clean is the power for noris network datacenter.de HOF1?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates noris network datacenter.de HOF1?
noris network.
Data centers near Hof
- Data center in Falkenstein 35.6 km · 19 MW
- Data center in Falkenstein 35.7 km · 9 MW
- Hetzner Online FSN1 (Falkenstein) 35.8 km · 26 MW
- Data center in Falkenstein 36.0 km · 8.2 MW
- Data center in Eckersdorf 53.0 km
- Carrierswitchraum Jena 67.9 km
- nbiserv 71.2 km
- Intershop-Tower Jena 71.4 km
More noris network data centers
- noris network datacenter.de NBG6 Germany
- noris network FRA1 Germany
- noris network datacenter.de MUC5 Germany
- noris network datacenter.de NBG3 / NBG4 Germany