Data center in Quincy
Data center in Quincy is an operational data center in Quincy, United States. Our footprint estimate of its power is about 13 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 13 MW (range 6.4 MW to 21 MW) Estimate from building footprint, low confidence. Footprint estimate: about 10,747 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 47.24621, -119.81323 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 230 kV, 4.1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 2 |
| Utility | PUD No 2 Of Grant County (political subdivision) Electric retail service territory (HIFLD, US government). |
| Balancing authority | GCPD |
| Nearest gas pipeline | Northwest Pipeline, interstate pipeline, 21 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.2 GW in 4 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 135 g CO₂ per kWh (Washington, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 62.8%, gas 15.7%, wind 8.3%, nuclear 7.5%, coal 3%. Clean power: 80.9% |
| Industrial power price | USD 0.074 per kWh (Washington, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.1 °C (2001 to 2025) |
| Cooling degree days | 327 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.11 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Low - Medium (10-20%) (Washington) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Quincy use?
We estimate the facility power at about 13 MW. Estimate from building footprint, low confidence.
How close is Data center in Quincy to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (230 kV), about 4.1 km away. The local utility is PUD No 2 Of Grant County, in the GCPD balancing area.
How clean is the power for Data center in Quincy?
The grid in Washington emits about 135 g CO₂ per kWh (2025). Largest sources: hydro 62.8%, gas 15.7%, wind 8.3%.
Data centers near Quincy
- Data center in Quincy 163 m · 20 MW
- Intergate.Quincy 188 m · 45 MW
- Data center in Quincy 245 m · 13 MW
- Data center in Quincy 399 m · 34 MW
- Vantage Quincy Campus 660 m · 27 MW
- H5 Data Center 731 m · 24 MW
- H5 Data Centers Quincy 852 m · 21 MW
- H5 Data Centers Quincy 2/3 903 m · 16 MW