DataPro Moscow II
DataPro Moscow II is an operational data center operated by DataPro in Khimki, Russia. Our footprint estimate of its power is about 1.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DataPro |
| Facility power | 1.8 MW (range 0.7 MW to 4.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 14,927 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 770 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 55.87940, 37.43382 |
Power and grid
| Nearest high-voltage substation | Химки, 110 kV, 1.2 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 220 kV, 2 km away |
| HV substations within 10 km | 48 |
| Power plants within 50 km | 13 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 447 g CO₂ per kWh (Russia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.6%, nuclear 18.3%, coal 17.7%, hydro 16.7%, oil and other fossil 1%. Clean power: 35.7% |
Climate and water
| Average temperature | 4.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.1 °C (2001 to 2025) |
| Cooling degree days | 86 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.8 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | Low - Medium (10-20%) (Russia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DataPro Moscow II use?
We estimate the facility power at about 1.8 MW. Estimate from building footprint, low confidence.
How close is DataPro Moscow II to the power grid?
The nearest high-voltage substation in OpenStreetMap is Химки (110 kV), about 1.2 km away.
How clean is the power for DataPro Moscow II?
The grid in Russia emits about 447 g CO₂ per kWh (2025). Largest sources: gas 45.6%, nuclear 18.3%, coal 17.7%.
Who operates DataPro Moscow II?
DataPro.
Data centers near Khimki
- Web Data Center 2.4 km
- Data center in Novokhovrino 4.8 km · 3.1 MW
- NORD-4 5.0 km · 5.2 MW
- Stack.HTH 8.7 km
- KIAEHOUSE 9.1 km
- IXcellerate MOS1 9.2 km · 21 MW
- 3data A35 9.4 km
- DataLine Moscow 1 9.4 km
More DataPro data centers
- DataPro VI Russia
- DataPro IV Russia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.