DCI Indonesia H2-02
DCI Indonesia H2-02 is an operational data center operated by DCI Indonesia in Karawang, Indonesia. Our footprint estimate of its power is about 80 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | DCI Indonesia |
| Facility power | 80 MW (range 40 MW to 128 MW) Estimate from building footprint, low confidence. Footprint estimate: about 11,104 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 34,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | DCI Indonesia H2-01 |
| Opened | 2022 |
| Coordinates | -6.40787, 107.25038 |
Power and grid
| Nearest high-voltage substation | Gardu Induk Margakarya, 150 kV, 2.6 km away (PLN) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | GITET Deltamas, 500 kV, 8.3 km away |
| HV substations within 10 km | 13 |
| Power plants within 50 km | 7.6 GW in 21 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 705 g CO₂ per kWh (Indonesia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 69.4%, gas 11.6%, hydro 6.7%, bioenergy 5.3%, other renewables 3.4%. Clean power: 15.8% |
Climate and water
| Average temperature | 25.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36 °C (2001 to 2025) |
| Cooling degree days | 2,715 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.01 kWh per m² per day |
| Wind at 50 m | 3.6 m/s average |
| Water stress today | Medium - High (20-40%) (Indonesia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does DCI Indonesia H2-02 use?
We estimate the facility power at about 80 MW. Estimate from building footprint, low confidence.
How close is DCI Indonesia H2-02 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Gardu Induk Margakarya (150 kV), about 2.6 km away.
How clean is the power for DCI Indonesia H2-02?
The grid in Indonesia emits about 705 g CO₂ per kWh (2025). Largest sources: coal 69.4%, gas 11.6%, hydro 6.7%.
Who operates DCI Indonesia H2-02?
DCI Indonesia.
Data centers near Karawang
- DCI Indonesia (H2-01) 552 m
- Microsoft JKT02 2.4 km · 15 MW
- Amazon Web Services 2.7 km · 8.4 MW
- Microsoft JKT09 3.4 km · 10 MW
- STT Jakarta 1 6.6 km · 22 MW
- STTGDC JKT1 6.6 km
- Amazon Web Services 7.4 km · 9.6 MW
- Microsoft JKT05 7.5 km · 14 MW
More DCI Indonesia data centers
- DCI Indonesia (E1) Indonesia
- DCI Indonesia (H2-01) Indonesia
- DCI Indonesia (JK1) Indonesia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.