EDGE1 (EG1) - Digital Edge JKT1 - Jakarta
EDGE1 (EG1) - Digital Edge JKT1 - Jakarta is an operational data center operated by Digital Edge Indonesia in Jakarta Selatan, Indonesia. Our footprint estimate of its power is about 8.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Edge Indonesia |
| Facility power | 8.3 MW (range 4.2 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,156 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 93 networks, 9 internet exchanges PeeringDB. |
| Also known as | EDGE1 |
| Address | Jl. Kuningan Barat Raya, Kuningan Bar., Kec. Mampang Prpt., |
| Coordinates | -6.23907, 106.82455 |
| Website | id.digitaledgedc.com/data-centers/edge1 |
Power and grid
| Nearest high-voltage substation | Gardu Induk Mampang Baru, 150 kV, 500 m away (Perusahaan Listrik Negara) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | GITET Gandul, 500 kV, 12.7 km away |
| HV substations within 10 km | 30 |
| Power plants within 50 km | 10 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 705 g CO₂ per kWh (Indonesia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 69.4%, gas 11.6%, hydro 6.7%, bioenergy 5.3%, other renewables 3.4%. Clean power: 15.8% |
Climate and water
| Average temperature | 27.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.2 °C (2001 to 2025) |
| Cooling degree days | 3,369 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.04 kWh per m² per day |
| Wind at 50 m | 3.9 m/s average |
| Water stress today | Medium - High (20-40%) (Indonesia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does EDGE1 (EG1) - Digital Edge JKT1 - Jakarta use?
We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.
How close is EDGE1 (EG1) - Digital Edge JKT1 - Jakarta to the power grid?
The nearest high-voltage substation in OpenStreetMap is Gardu Induk Mampang Baru (150 kV), about 500 m away.
How clean is the power for EDGE1 (EG1) - Digital Edge JKT1 - Jakarta?
The grid in Indonesia emits about 705 g CO₂ per kWh (2025). Largest sources: coal 69.4%, gas 11.6%, hydro 6.7%.
Who operates EDGE1 (EG1) - Digital Edge JKT1 - Jakarta?
Digital Edge Indonesia.
Data centers near Jakarta Selatan
- CNI/ISC DC CBR 67 m
- Argon Data Communication 68 m
- NEX Datacenter (NEX-JK2) Jakarta 72 m
- ProDC 81 m
- Datacenter APJII-Cyber JAKARTA 120 m
- NTT Jakarta 2 Data Center (JKT2) 170 m · 18 MW
- Equinix 254 m · 11 MW
- Herza DC - Tifa 298 m
More Digital Edge Indonesia data centers