NTT Jakarta 2 Data Center (JKT2)

NTT Jakarta 2 Data Center (JKT2) is an operational data center operated by NTT Global Data Centers in Jakarta, Indonesia. Our footprint estimate of its power is about 18 MW.

Key facts

StatusOperational
OperatorNTT Global Data Centers
Facility power18 MW (range 9.2 MW to 29 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,547 m² building outline x 6 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks250 networks, 13 internet exchanges
PeeringDB.
Also known asIPDN Data Center · Cyber Tower
AddressJalan Kuningan Barat No.8 NTT building, Kuningan Barat, Mampang Prapatan, Kota Jakarta (inside Cyber Area)
Coordinates-6.23800, 106.82345
Websiteservices.global.ntt/en-us/services-and-products/global-data-centers/global-locations/asia-pacific/jakarta-2-data-center

Power and grid

Nearest high-voltage substationGardu Induk Mampang Baru, 150 kV, 300 m away (Perusahaan Listrik Negara)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationGISTET Kembangan, 500 kV, 12.7 km away
HV substations within 10 km31
Power plants within 50 km10 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity705 g CO₂ per kWh (Indonesia, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 69.4%, gas 11.6%, hydro 6.7%, bioenergy 5.3%, other renewables 3.4%. Clean power: 15.8%

Climate and water

Average temperature27.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.2 °C (2001 to 2025)
Cooling degree days3,369 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.04 kWh per m² per day
Wind at 50 m3.9 m/s average
Water stress todayMedium - High (20-40%) (Indonesia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does NTT Jakarta 2 Data Center (JKT2) use?

We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.

How close is NTT Jakarta 2 Data Center (JKT2) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Gardu Induk Mampang Baru (150 kV), about 300 m away.

How clean is the power for NTT Jakarta 2 Data Center (JKT2)?

The grid in Indonesia emits about 705 g CO₂ per kWh (2025). Largest sources: coal 69.4%, gas 11.6%, hydro 6.7%.

Who operates NTT Jakarta 2 Data Center (JKT2)?

NTT Global Data Centers.

Data centers near Jakarta

More NTT Global Data Centers data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.