NTT Jakarta 2 Data Center (JKT2)
NTT Jakarta 2 Data Center (JKT2) is an operational data center operated by NTT Global Data Centers in Jakarta, Indonesia. Our footprint estimate of its power is about 18 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 18 MW (range 9.2 MW to 29 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,547 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 250 networks, 13 internet exchanges PeeringDB. |
| Also known as | IPDN Data Center · Cyber Tower |
| Address | Jalan Kuningan Barat No.8 NTT building, Kuningan Barat, Mampang Prapatan, Kota Jakarta (inside Cyber Area) |
| Coordinates | -6.23800, 106.82345 |
| Website | services.global.ntt/en-us/services-and-products/global-data-centers/global-locations/asia-pacific/jakarta-2-data-center |
Power and grid
| Nearest high-voltage substation | Gardu Induk Mampang Baru, 150 kV, 300 m away (Perusahaan Listrik Negara) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | GISTET Kembangan, 500 kV, 12.7 km away |
| HV substations within 10 km | 31 |
| Power plants within 50 km | 10 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 705 g CO₂ per kWh (Indonesia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 69.4%, gas 11.6%, hydro 6.7%, bioenergy 5.3%, other renewables 3.4%. Clean power: 15.8% |
Climate and water
| Average temperature | 27.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.2 °C (2001 to 2025) |
| Cooling degree days | 3,369 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.04 kWh per m² per day |
| Wind at 50 m | 3.9 m/s average |
| Water stress today | Medium - High (20-40%) (Indonesia) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Jakarta 2 Data Center (JKT2) use?
We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.
How close is NTT Jakarta 2 Data Center (JKT2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Gardu Induk Mampang Baru (150 kV), about 300 m away.
How clean is the power for NTT Jakarta 2 Data Center (JKT2)?
The grid in Indonesia emits about 705 g CO₂ per kWh (2025). Largest sources: coal 69.4%, gas 11.6%, hydro 6.7%.
Who operates NTT Jakarta 2 Data Center (JKT2)?
NTT Global Data Centers.
Data centers near Jakarta
- Datacenter APJII-Cyber JAKARTA 50 m
- Equinix 88 m · 11 MW
- CNI/ISC DC CBR 109 m
- Argon Data Communication 112 m
- Herza DC - Tifa 150 m
- EDGE1 (EG1) - Digital Edge JKT1 - Jakarta 170 m · 8.3 MW
- NEX Datacenter (NEX-JK2) Jakarta 219 m
- ProDC 243 m
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.