NTTData Data Center
NTTData Data Center is an operational data center operated by NTT Global Data Centers in Quincy, United States. Our footprint estimate of its power is about 29 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 29 MW (range 12 MW to 72 MW) Estimate from building footprint, low confidence. Footprint estimate: about 239,609 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 12,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | NTT Data Quincy |
| Coordinates | 47.24465, -119.86468 |
Power and grid
| Utility | PUD No 2 Of Grant County (political subdivision) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | GCPD |
| Nearest gas pipeline | Northwest Pipeline, interstate pipeline, 17.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 135 g CO₂ per kWh (Washington, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 62.8%, gas 15.7%, wind 8.3%, nuclear 7.5%, coal 3%. Clean power: 80.9% |
| Industrial power price | USD 0.074 per kWh (Washington, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.1 °C (2001 to 2025) |
| Cooling degree days | 327 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.11 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Low - Medium (10-20%) (Washington) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTTData Data Center use?
We estimate the facility power at about 29 MW. Estimate from building footprint, low confidence.
How clean is the power for NTTData Data Center?
The grid in Washington emits about 135 g CO₂ per kWh (2025). Largest sources: hydro 62.8%, gas 15.7%, wind 8.3%.
Who operates NTTData Data Center?
NTT Global Data Centers.
Data centers near Quincy
- CyrusOne Quincy 387 m · 16 MW
- Microsoft Columbia Data Center 637 m · 30 MW
- Data center in Quincy 816 m · 2.7 MW
- Azure OpenAI GPT-3 Cluster 1.7 km · 6.6 MW
- Microsoft 1.8 km · 13 MW
- Data center in Quincy 2.4 km · 19 MW
- Data center in Quincy 2.6 km · 3 MW
- Yahoo Data Center 2.9 km · 25 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
- NTT RagingWire DC - Hillsboro United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.