FIS-ASP data center in Schweinfurt
FIS-ASP data center in Schweinfurt is an operational data center operated by FIS-ASP in Schweinfurt, Germany. Our footprint estimate of its power is about 1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | FIS-ASP |
| Facility power | 1 MW (range 0.5 MW to 1.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 812 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 430 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 49.99654, 10.20337 |
Power and grid
| Nearest high-voltage substation | Grafenrheinfeld, 380 kV, 2 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 12 |
| Power plants within 50 km | 610 MW in 41 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39 °C (2001 to 2025) |
| Cooling degree days | 172 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does FIS-ASP data center in Schweinfurt use?
We estimate the facility power at about 1 MW. Estimate from building footprint, low confidence.
How close is FIS-ASP data center in Schweinfurt to the power grid?
The nearest high-voltage substation in OpenStreetMap is Grafenrheinfeld (380 kV), about 2 km away.
How clean is the power for FIS-ASP data center in Schweinfurt?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates FIS-ASP data center in Schweinfurt?
FIS-ASP.
Data centers near Schweinfurt
- RegioNet Schweinfurt GmbH 6.2 km
- euNetworks Colocation Wuerzburg 27.5 km
- rockenstein AG 27.8 km · 2.2 MW
- Datacenter Mainfranken 28.8 km
- Datenstelle der Rentenversicherung 33.0 km · 4.8 MW
- centron DC bbg 48.2 km
- Stadtnetz Bamberg 50.0 km
- UNITED COLO GmbH / NGZ-Server.de Coburg 61.0 km