rockenstein AG
rockenstein AG is an operational data center in Veitshöchheim, Germany. Our footprint estimate of its power is about 2.2 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 2.2 MW (range 1.1 MW to 3.5 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,808 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 940 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Schleehofstraße 16, 97209, Veitshöchheim |
| Coordinates | 49.83356, 9.90845 |
| Website | rockenstein.de |
Power and grid
| Nearest high-voltage substation | Umspannwerk Dürrbachau, 110 kV, 3.3 km away (Bayernwerk Netz) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Trennfeld, 220 kV, 22.9 km away |
| HV substations within 10 km | 4 |
| Power plants within 50 km | 440 MW in 32 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39 °C (2001 to 2025) |
| Cooling degree days | 172 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does rockenstein AG use?
We estimate the facility power at about 2.2 MW. Estimate from building footprint, low confidence.
How close is rockenstein AG to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Dürrbachau (110 kV), about 3.3 km away.
How clean is the power for rockenstein AG?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Data centers near Veitshöchheim
- Datacenter Mainfranken 4.5 km
- euNetworks Colocation Wuerzburg 5.9 km
- Datenstelle der Rentenversicherung 10.3 km · 4.8 MW
- FIS-ASP data center in Schweinfurt 27.8 km · 1 MW
- RegioNet Schweinfurt GmbH 32.8 km
- EnormateGreenCenter 66.6 km
- STACKIT Ellhofen (DC08) 87.9 km · 1.7 MW
- JH-Computers data center in Dinkelsbühl 96.4 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.