STACKIT Ellhofen (DC08)

STACKIT Ellhofen (DC08) is an operational data center operated by Schwarz IT KG in Ellhofen, Germany. Our footprint estimate of its power is about 1.7 MW.

Key facts

StatusOperational
OperatorSchwarz IT KG
Facility power1.7 MW (range 0.8 MW to 2.7 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,384 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 730 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks1 networks
PeeringDB.
Also known asRechenzentrum Ellhofen
AddressAm AK 14
Coordinates49.14591, 9.30796
Websitestackit.de/de/colocation/dc-08

Power and grid

Nearest high-voltage substationUmspannwerk Weinsberg, 110 kV, 2.1 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationHeilbronn, 380 kV, 8.1 km away
HV substations within 10 km10
Power plants within 50 km2.9 GW in 36 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.7 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38.5 °C (2001 to 2025)
Cooling degree days187 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.17 kWh per m² per day
Wind at 50 m5.8 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does STACKIT Ellhofen (DC08) use?

We estimate the facility power at about 1.7 MW. Estimate from building footprint, low confidence.

How close is STACKIT Ellhofen (DC08) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Umspannwerk Weinsberg (110 kV), about 2.1 km away.

How clean is the power for STACKIT Ellhofen (DC08)?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Who operates STACKIT Ellhofen (DC08)?

Schwarz IT KG.

Data centers near Ellhofen

More Schwarz IT KG data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.