Free Pro - Datacenter Marseille (MAR02)
Free Pro - Datacenter Marseille (MAR02) is an operational data center operated by Free Pro (Ex. Jaguar Network - DCForData) in Marseille 16, France. Our footprint estimate of its power is about 7.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Free Pro (Ex. Jaguar Network - DCForData) |
| Facility power | 7.8 MW (range 3.9 MW to 12 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,474 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Telehouse THM1 |
| Coordinates | 43.36120, 5.33793 |
Power and grid
| Nearest high-voltage substation | Poste électrique de Saumaty, 225 kV, 700 m away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 11 |
| Power plants within 50 km | 3.2 GW in 55 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 14.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41 °C (2001 to 2025) |
| Cooling degree days | 591 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.44 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Free Pro - Datacenter Marseille (MAR02) use?
We estimate the facility power at about 7.8 MW. Estimate from building footprint, low confidence.
How close is Free Pro - Datacenter Marseille (MAR02) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique de Saumaty (225 kV), about 700 m away.
How clean is the power for Free Pro - Datacenter Marseille (MAR02)?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Free Pro - Datacenter Marseille (MAR02)?
Free Pro (Ex. Jaguar Network - DCForData).
Data centers near Marseille 16
- Free Pro - Marseille - MRS1 177 m
- Digital Realty MRS3 2.6 km · 32 MW
- EXA Edge DC Marseille 3.2 km · 2.2 MW
- Verizon Marseille 3.4 km · 1.1 MW
- Marseille St-Mauront 5.9 km · 7 MW
- PHOCEA DC-M1 6.3 km
- Digital Realty Marseille MRS1/2/3/4 6.3 km · 25 MW
- Datacenter Sud 6.6 km
More Free Pro (Ex. Jaguar Network - DCForData) data centers
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.