GIP Dallas
GIP Dallas is an operational data center operated by Global IP Networks in Dallas, United States. Our footprint estimate of its power is about 46 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Global IP Networks |
| Facility power | 46 MW (range 23 MW to 74 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,407 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 20,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 4 networks PeeringDB. |
| Also known as | Spin Servers DAL1 · Live Oak Data Center |
| Address | 2020 Live Oak St. |
| Coordinates | 32.78382, -96.79463 |
| Website | gipnetworks.com |
Power and grid
| Utility | Hilco Electric Cooperative, INC. (cooperative) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Gulf South Pipeline Co, interstate pipeline, 6.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 1,559 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does GIP Dallas use?
We estimate the facility power at about 46 MW. Estimate from building footprint, low confidence.
How clean is the power for GIP Dallas?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates GIP Dallas?
Global IP Networks.
Data centers near Dallas
- Digital Realty DFW (2323 Bryan St) 379 m
- Opus Interactive Dallas (DTX01) 709 m · 5.6 MW
- VIRTBIZ 1.1 km
- Flexential Dallas - Downtown Dallas 3.0 km
- Equinix DA1 - Dallas 3.0 km · 196 MW
- Colo4Dallas 6.4 km · 8.3 MW
- Level(3) Dallas 7.4 km · 7 MW
- CoreSpace Dallas 8.2 km · 6.8 MW
More Global IP Networks data centers
- GIP Plano United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.