Opus Interactive Dallas (DTX01)
Opus Interactive Dallas (DTX01) is an operational data center operated by Opus Interactive in Dallas, United States. Our footprint estimate of its power is about 5.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Opus Interactive |
| Facility power | 5.6 MW (range 2.8 MW to 9 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,662 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 45 networks, 4 internet exchanges PeeringDB. |
| Also known as | DataBank Dallas (DFW1) · DataBank · Rad Web Hosting |
| Address | 400 S. Akard |
| Coordinates | 32.77829, -96.79840 |
| Website | opusinteractive.com/datacenter-locations |
Power and grid
| Utility | Hilco Electric Cooperative, INC. (cooperative) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Gulf South Pipeline Co, interstate pipeline, 6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 1,559 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Opus Interactive Dallas (DTX01) use?
We estimate the facility power at about 5.6 MW. Estimate from building footprint, low confidence.
How clean is the power for Opus Interactive Dallas (DTX01)?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Opus Interactive Dallas (DTX01)?
Opus Interactive.
Data centers near Dallas
- GIP Dallas 709 m · 46 MW
- Digital Realty DFW (2323 Bryan St) 1.1 km
- VIRTBIZ 1.5 km
- Flexential Dallas - Downtown Dallas 3.1 km
- Equinix DA1 - Dallas 3.2 km · 196 MW
- Colo4Dallas 6.4 km · 8.3 MW
- Level(3) Dallas 7.3 km · 7 MW
- CoreSpace Dallas 8.2 km · 6.8 MW
More Opus Interactive data centers
- Opus Interactive Silicon Valley (SJC01) United States
- Opus Interactive Portland (PDX01) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.