Hauszmann adatközpont
Hauszmann adatközpont is an operational data center in Budapest, Hungary. Our footprint estimate of its power is about 5.2 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 5.2 MW (range 2.6 MW to 8.3 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,083 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Hauszmann Alajos utca 3/a, 1117, Budapest |
| Coordinates | 47.46663, 19.04601 |
Power and grid
| Nearest high-voltage substation | Lágymányos alállomás, 132 kV, 700 m away (ELMŰ) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Albertfalva alállomás, 220 kV, 3 km away |
| HV substations within 10 km | 26 |
| Power plants within 50 km | 1.9 GW in 19 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 162 g CO₂ per kWh (Hungary, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 40.1%, solar 27.1%, gas 20.3%, bioenergy 6%, coal 3.3%. Clean power: 75.4% |
| Industrial power price | EUR 0.176 per kWh (Hungary, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40 °C (2001 to 2025) |
| Cooling degree days | 392 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.48 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Low (<10%) (Hungary) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Hauszmann adatközpont use?
We estimate the facility power at about 5.2 MW. Estimate from building footprint, low confidence.
How close is Hauszmann adatközpont to the power grid?
The nearest high-voltage substation in OpenStreetMap is Lágymányos alállomás (132 kV), about 700 m away.
How clean is the power for Hauszmann adatközpont?
The grid in Hungary emits about 162 g CO₂ per kWh (2025). Largest sources: nuclear 40.1%, solar 27.1%, gas 20.3%.
Data centers near Budapest
- Yettel Budafok MSC 1.0 km
- Belügyminisztérium Nyilvántartások Vezetéséért Felelős Helyettes Államtitkárság 2.9 km · 2.4 MW
- Dataplex Budapest 5.0 km
- Magyar Telekom Cloud & DataCenter 5.3 km · 44 MW
- BIX Building (Victor Hugo street) 5.8 km
- ATW data center in Budapest 5.8 km
- Invitech DC14 6.1 km
- Magyar Telekom data center in Budaörs 6.1 km · 3.1 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.