Magyar Telekom Cloud & DataCenter
Magyar Telekom Cloud & DataCenter is an operational data center operated by Telekom Rendszerintegráció Zrt. in Budapest, Hungary. Our footprint estimate of its power is about 44 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Telekom Rendszerintegráció Zrt. |
| Facility power | 44 MW (range 22 MW to 70 MW) Estimate from building footprint, low confidence. Footprint estimate: about 18,342 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 19,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Asztalos Sándor út 13, 1087, Budapest |
| Coordinates | 47.49360, 19.10363 |
Power and grid
| Nearest high-voltage substation | Ganz MÁVAG alállomás, 132 kV, 700 m away (Ganz Szolgáltató) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Zugló alállomás, 220 kV, 4.8 km away |
| HV substations within 10 km | 32 |
| Power plants within 50 km | 2.1 GW in 22 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 162 g CO₂ per kWh (Hungary, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 40.1%, solar 27.1%, gas 20.3%, bioenergy 6%, coal 3.3%. Clean power: 75.4% |
| Industrial power price | EUR 0.176 per kWh (Hungary, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40 °C (2001 to 2025) |
| Cooling degree days | 392 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.48 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Low (<10%) (Budapest) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Magyar Telekom Cloud & DataCenter use?
We estimate the facility power at about 44 MW. Estimate from building footprint, low confidence.
How close is Magyar Telekom Cloud & DataCenter to the power grid?
The nearest high-voltage substation in OpenStreetMap is Ganz MÁVAG alállomás (132 kV), about 700 m away.
How clean is the power for Magyar Telekom Cloud & DataCenter?
The grid in Hungary emits about 162 g CO₂ per kWh (2025). Largest sources: nuclear 40.1%, solar 27.1%, gas 20.3%.
Who operates Magyar Telekom Cloud & DataCenter?
Telekom Rendszerintegráció Zrt..
Data centers near Budapest
- DoclerNet 1.1 km
- Invitech DC14 1.7 km
- Belügyminisztérium Nyilvántartások Vezetéséért Felelős Helyettes Államtitkárság 2.5 km · 2.4 MW
- ATW data center in Budapest 4.3 km
- BIX Building (Victor Hugo street) 4.5 km
- Dataplex Budapest 5.0 km
- VIVAnet DC 5.2 km
- Hauszmann adatközpont 5.3 km · 5.2 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.