Hub Europe
Hub Europe is an operational data center operated by Contabo in Durmersheim, Germany. Our footprint estimate of its power is about 1.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Contabo |
| Facility power | 1.5 MW (range 0.6 MW to 3.7 MW) Estimate from building footprint, low confidence. Footprint estimate: about 12,449 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 640 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Building 1 · Building 2 |
| Coordinates | 48.95532, 8.18071 |
| Website | contabo.com/blog/welcome-to-hub-europe-new-data-center-for-all-your-cloud-needs |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 8.7 km away (Netze BW) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Poste électrique de Seltz, 225 kV, 9.3 km away |
| HV substations within 10 km | 3 |
| Power plants within 50 km | 2.3 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 262 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.17 kWh per m² per day |
| Wind at 50 m | 5.5 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Hub Europe use?
We estimate the facility power at about 1.5 MW. Estimate from building footprint, low confidence.
How close is Hub Europe to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 8.7 km away.
How clean is the power for Hub Europe?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Hub Europe?
Contabo.
Data centers near Durmersheim
- 1&1 Internet SE data center in Hagenbach 4.3 km · 2.2 MW
- TelemaxX IPC1 13.8 km · 1.3 MW
- Karlsruher Institut für Technologie HoreKa 17.2 km · 0.6 MW
- Scientific Computing Center - KIT CS 17.8 km
- KIT-Bibliothek Süd 18.3 km
- POP Technologiepark Karlsruhe 20.2 km
- euNetworks Colocation Karlsruhe 20.3 km · 1.4 MW
- TelemaxX IPC4 22.8 km · 3.3 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.