POP Technologiepark Karlsruhe
POP Technologiepark Karlsruhe is an operational data center operated by TelemaxX Telekommunikation in Karlsruhe, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | TelemaxX Telekommunikation |
| Networks | 1 networks PeeringDB. |
| Also known as | TelemaxX IPC2 |
| Address | Emmy-Noether Straße 9 |
| Coordinates | 49.01954, 8.43993 |
| Website | telemaxx.de |
Power and grid
| Nearest high-voltage substation | Umspannwerk Blöße, 110 kV, 900 m away (Stadtwerke Karlsruhe Netzservice GmbH) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Karlsruhe Ost, 220 kV, 1.6 km away |
| HV substations within 10 km | 27 |
| Power plants within 50 km | 4.2 GW in 34 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.5 °C (2001 to 2025) |
| Cooling degree days | 179 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.17 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is POP Technologiepark Karlsruhe to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Blöße (110 kV), about 900 m away.
How clean is the power for POP Technologiepark Karlsruhe?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates POP Technologiepark Karlsruhe?
TelemaxX Telekommunikation.
Data centers near Karlsruhe
- euNetworks Colocation Karlsruhe 77 m · 1.4 MW
- KIT-Bibliothek Süd 2.0 km
- Scientific Computing Center - KIT CS 2.5 km
- TelemaxX IPC4 2.6 km · 3.3 MW
- TelemaxX IPC3 2.8 km · 1.2 MW
- Karlsruher Institut für Technologie HoreKa 3.0 km · 0.6 MW
- TelemaxX IPC5 6.6 km · 4 MW
- TelemaxX IPC1 6.8 km · 1.3 MW
More TelemaxX Telekommunikation data centers
- TelemaxX IPC5 Germany
- TelemaxX IPC4 Germany
- TelemaxX IPC1 Germany
- TelemaxX IPC3 Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.