intersaar SB3
intersaar SB3 is an operational data center operated by Intersaar in Saarbrücken, Germany. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Intersaar |
| Networks | 3 networks, 1 internet exchanges PeeringDB. |
| Address | Nell-Breuning-Allee 6, 66115 Saarbrücken |
| Coordinates | 49.24038, 6.95546 |
| Website | intersaar.de |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 500 m away (SWS) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Poste électrique de Petite Rosselle, 225 kV, 7.1 km away |
| HV substations within 10 km | 16 |
| Power plants within 50 km | 3.4 GW in 53 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.8 °C (2001 to 2025) |
| Cooling degree days | 159 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.15 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Medium - High (20-40%) (Saarland) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is intersaar SB3 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 500 m away.
How clean is the power for intersaar SB3?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates intersaar SB3?
Intersaar.
Data centers near Saarbrücken
- Open Skies One 6.3 km
- Rechenzentrum 6.8 km
- Inexio 17.0 km · 5.3 MW
- Net-Build GmbH 18.1 km
- Rechenzentrum KÜS Data 31.4 km · 3.7 MW
- Advanced MedioMatrix 54.5 km
- Advanced Mediomatrix 55.0 km · 13 MW
- Neo Center Est 57.5 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.