Data Center Directory

Rechenzentrum KÜS Data

Rechenzentrum KÜS Data is an operational data center in Losheim am See, Germany. Our footprint estimate of its power is about 3.7 MW.

Key facts

StatusOperational
Facility power3.7 MW (range 1.8 MW to 5.9 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,539 m² building outline x 2 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressProf.-Pirlet-Straße 27-29, 66679, Losheim am See
Coordinates49.50505, 6.80425

Power and grid

Nearest high-voltage substationUnnamed substation, 110 kV, 400 m away (Energis)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationDiefflen, 220 kV, 16 km away
HV substations within 10 km4
Power plants within 50 km8.7 GW in 71 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature38.6 °C (2001 to 2025)
Cooling degree days115 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.15 kWh per m² per day
Wind at 50 m6.1 m/s average
Water stress todayMedium - High (20-40%) (Saarland)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Rechenzentrum KÜS Data use?

We estimate the facility power at about 3.7 MW. Estimate from building footprint, low confidence.

How close is Rechenzentrum KÜS Data to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 400 m away.

How clean is the power for Rechenzentrum KÜS Data?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Data centers near Losheim am See