Lloyds Banking Group Copley
Lloyds Banking Group Copley is an operational data center in Halifax, United Kingdom. Our footprint estimate of its power is about 32 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 32 MW (range 16 MW to 51 MW) Estimate from building footprint, low confidence. Footprint estimate: about 26,643 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 14,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 53.70843, -1.88445 |
Power and grid
| Nearest high-voltage substation | Sowerby Bridge, 132 kV, 2.6 km away (Northern Powergrid) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Elland Substation, 275 kV, 4.4 km away |
| HV substations within 10 km | 7 |
| Power plants within 50 km | 2.7 GW in 63 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 8.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 29.7 °C (2001 to 2025) |
| Cooling degree days | 7 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.73 kWh per m² per day |
| Wind at 50 m | 7.3 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Lloyds Banking Group Copley use?
We estimate the facility power at about 32 MW. Estimate from building footprint, low confidence.
How close is Lloyds Banking Group Copley to the power grid?
The nearest high-voltage substation in OpenStreetMap is Sowerby Bridge (132 kV), about 2.6 km away.
How clean is the power for Lloyds Banking Group Copley?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Data centers near Halifax
- Elland DC 4.0 km
- Sungard AS Elland TC4 4.5 km
- Redcentric Elland Data Centre 4.5 km · 14 MW
- Legend Bradford 12.5 km
- Templus DC Leeds LEE01 21.3 km
- GridJet 22.1 km · 1 MW
- aql DC5 24.0 km
- aql DC2 24.5 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.