Mittwald CM Service GmbH & Co. KG data center in Espelkamp
Mittwald CM Service GmbH & Co. KG data center in Espelkamp is an operational data center operated by Mittwald CM Service GmbH & Co. KG in Espelkamp, Germany. Our footprint estimate of its power is about 0.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Mittwald CM Service GmbH & Co. KG |
| Facility power | 0.7 MW (range 0.4 MW to 1.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 595 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 52.38557, 8.62359 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 110 kV, 100 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Schaltanlage Ovenstädt, 380 kV, 21.5 km away |
| HV substations within 10 km | 5 |
| Power plants within 50 km | 348 MW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.2 °C (2001 to 2025) |
| Cooling degree days | 99 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.85 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Mittwald CM Service GmbH & Co. KG data center in Espelkamp use?
We estimate the facility power at about 0.7 MW. Estimate from building footprint, low confidence.
How close is Mittwald CM Service GmbH & Co. KG data center in Espelkamp to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (110 kV), about 100 m away.
How clean is the power for Mittwald CM Service GmbH & Co. KG data center in Espelkamp?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Mittwald CM Service GmbH & Co. KG data center in Espelkamp?
Mittwald CM Service GmbH & Co. KG.
Data centers near Espelkamp
- partimus Rechenzentrum Bad Oeynhausen 21.1 km
- DTS DataCenter Herford 29.6 km
- euNetworks Colocation Bielefeld 40.9 km
- BITel Bielefeld 42.1 km
- Gebäude 94/95 42.4 km · 2.4 MW
- BICOS COMPUTER GmbH 44.0 km
- BITel Gütersloh 54.0 km
- Data center in Gütersloh 57.1 km · 2.2 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.