MK Netzdienste Datacenter

MK Netzdienste Datacenter is an operational data center operated by MK Netzdienste in Frankfurt am Main, Germany. Our footprint estimate of its power is about 1.2 MW.

Key facts

StatusOperational
OperatorMK Netzdienste
Facility power1.2 MW (range 0.6 MW to 1.9 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 997 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 510 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks37 networks, 4 internet exchanges
PeeringDB.
Also known asMK Netzdienste GmbH FRA2
AddressWilhelm-Fay-Straße 23
Coordinates50.12668, 8.58171
Websitemk.de

Power and grid

Nearest high-voltage substationWesterbach, 110 kV, 1.1 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationUmspannwerk Frankfurt Südwest, 380 kV, 4.6 km away
HV substations within 10 km35
Power plants within 50 km3.3 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity334 g CO₂ per kWh (Germany, 2025)
Average of all power made in the area. Ember.
Grid power mixwind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5%
Industrial power priceEUR 0.146 per kWh (Germany, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.8 °C (2001 to 2025)
Cooling degree days233 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.98 kWh per m² per day
Wind at 50 m5.7 m/s average
Water stress todayMedium - High (20-40%) (Germany)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does MK Netzdienste Datacenter use?

We estimate the facility power at about 1.2 MW. Estimate from building footprint, low confidence.

How close is MK Netzdienste Datacenter to the power grid?

The nearest high-voltage substation in OpenStreetMap is Westerbach (110 kV), about 1.1 km away.

How clean is the power for MK Netzdienste Datacenter?

The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.

Who operates MK Netzdienste Datacenter?

MK Netzdienste.