NTT Global Data Centers data center in Frankfurt am Main
NTT Global Data Centers data center in Frankfurt am Main is an operational data center operated by NTT Global Data Centers in Frankfurt am Main, Germany. Our footprint estimate of its power is about 2.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | NTT Global Data Centers |
| Facility power | 2.1 MW (range 1.1 MW to 3.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,752 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Breitlacherstraße 96, 60489, Frankfurt am Main |
| Coordinates | 50.12793, 8.60492 |
Power and grid
| Nearest high-voltage substation | Bahnstrom Unterwerk Frankfurt-Rödelheim, 110 kV, 1.6 km away (DB Energie) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Südwest, 380 kV, 4.1 km away |
| HV substations within 10 km | 34 |
| Power plants within 50 km | 3.3 GW in 44 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does NTT Global Data Centers data center in Frankfurt am Main use?
We estimate the facility power at about 2.1 MW. Estimate from building footprint, low confidence.
How close is NTT Global Data Centers data center in Frankfurt am Main to the power grid?
The nearest high-voltage substation in OpenStreetMap is Bahnstrom Unterwerk Frankfurt-Rödelheim (110 kV), about 1.6 km away.
How clean is the power for NTT Global Data Centers data center in Frankfurt am Main?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates NTT Global Data Centers data center in Frankfurt am Main?
NTT Global Data Centers.
Data centers near Frankfurt am Main
- NTT Frankfurt 1 Data Center (FRA1) 250 m · 10 MW
- Global Switch Frankfurt 539 m · 2.6 MW
- Colt FRA3 1.3 km · 5.8 MW
- Digital Realty Frankfurt FRA29-32 1.4 km · 3.3 MW
- CyrusOne Frankfurt 1 1.6 km · 5.9 MW
- MK Netzdienste Datacenter 1.7 km · 1.2 MW
- CyrusOne FRA3 2.0 km · 67 MW
- CyrusOne Frankfurt 4 2.1 km · 6.3 MW
More NTT Global Data Centers data centers
- NTT VA10 United States
- NTT Frankfurt 2 Data Center (FRA2) Germany
- NTT PH1 Datacenter United States
- NTT Japan
- NTTData Data Center United States
- NTT Hemel Hempstead 4 Data Center (HH4) United Kingdom
- NTT Berlin 1 Data Center (BER1) Germany
- NTT London 1 United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.