OpenColo
OpenColo is an operational data center operated by Energy Group Networks in Santa Clara, United States. Our footprint estimate of its power is about 5.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Energy Group Networks |
| Facility power | 5.8 MW (range 2.9 MW to 9.3 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,819 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 25 networks, 3 internet exchanges PeeringDB. |
| Address | 3223 Kenneth St |
| Coordinates | 37.37889, -121.95625 |
| Website | opencolo.com/our-facility |
Power and grid
| Utility | City Of Santa Clara (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 1.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 370 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.32 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does OpenColo use?
We estimate the facility power at about 5.8 MW. Estimate from building footprint, low confidence.
How clean is the power for OpenColo?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates OpenColo?
Energy Group Networks.
Data centers near Santa Clara
- Equinix SV2 - Silicon Valley, Santa Clara 125 m · 7.3 MW
- Digital Realty SJC (3105 Alfred St) 179 m · 4.1 MW
- Evocative SJC3 209 m · 2.7 MW
- Digital Realty SJC (3205 Alfred St) 218 m
- Csquare SFO4 348 m · 2.8 MW
- Centersquare Silicon Valley (SFO4-A) 366 m · 2.6 MW
- Condor Galaxy 1 (CG-1) 368 m · 2.2 MW
- Lumen Santa Clara 424 m · 2.5 MW