Equinix SV2 - Silicon Valley, Santa Clara
Equinix SV2 - Silicon Valley, Santa Clara is an operational data center operated by Equinix in Santa Clara, United States. Our footprint estimate of its power is about 7.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 7.3 MW (range 3.6 MW to 12 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,057 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 24 networks, 2 internet exchanges PeeringDB. |
| Also known as | Equinix Santa Clara SV2 |
| Address | 1350 Duane Ave |
| Coordinates | 37.37846, -121.95494 |
| Website | equinix.com/locations/americas-colocation/united-states-colocation/silicon-valley-data-centers/sv2 |
Power and grid
| Nearest high-voltage substation | Scott Receiving Station, 115 kV, 200 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Northern Receiving Station, 230 kV, 2.8 km away |
| HV substations within 10 km | 24 |
| Utility | City Of Santa Clara (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 1.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.1 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 370 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.32 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix SV2 - Silicon Valley, Santa Clara use?
We estimate the facility power at about 7.3 MW. Estimate from building footprint, low confidence.
How close is Equinix SV2 - Silicon Valley, Santa Clara to the power grid?
The nearest high-voltage substation in OpenStreetMap is Scott Receiving Station (115 kV), about 200 m away. The local utility is City Of Santa Clara, in the CISO balancing area.
How clean is the power for Equinix SV2 - Silicon Valley, Santa Clara?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates Equinix SV2 - Silicon Valley, Santa Clara?
Equinix.
Data centers near Santa Clara
- Evocative SJC3 85 m · 2.7 MW
- OpenColo 125 m · 5.8 MW
- Condor Galaxy 1 (CG-1) 254 m · 2.2 MW
- Digital Realty SJC (3105 Alfred St) 281 m · 4.1 MW
- Lumen Santa Clara 301 m · 2.5 MW
- Centersquare Silicon Valley (SFO4-A) 306 m · 2.6 MW
- Csquare SFO4 322 m · 2.8 MW
- Digital Realty SJC (1100 Space Park) 327 m · 14 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.