Pfalzkom DCRN I
Pfalzkom DCRN I is an operational data center operated by Pfalzkom in Mutterstadt, Germany. Our footprint estimate of its power is about 5.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Pfalzkom |
| Facility power | 5.7 MW (range 2.9 MW to 9.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,383 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks, 1 internet exchanges PeeringDB. |
| Also known as | Rechenzentrum PFALZKOM, DCRN I |
| Address | An der Fohlenweide 2 |
| Coordinates | 49.42591, 8.36025 |
| Website | pfalzkom.de |
Power and grid
| Nearest high-voltage substation | Umspannwerk Mutterstadt, 110 kV, 200 m away (Pfalzwerke Netz AG) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | UA Mutterstadt, 220 kV, 800 m away |
| HV substations within 10 km | 6 |
| Power plants within 50 km | 5.4 GW in 38 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.5 °C (2001 to 2025) |
| Cooling degree days | 213 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.17 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Low (<10%) (Rheinland-Pfalz) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Pfalzkom DCRN I use?
We estimate the facility power at about 5.7 MW. Estimate from building footprint, low confidence.
How close is Pfalzkom DCRN I to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Mutterstadt (110 kV), about 200 m away.
How clean is the power for Pfalzkom DCRN I?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates Pfalzkom DCRN I?
Pfalzkom.
Data centers near Mutterstadt
- Pfalzkom DCRN II 928 m · 5.7 MW
- TWL-KOM Datacenter II 8.0 km
- euNetworks Colocation Mannheim 10.8 km
- nexspace data centers Heidelberg 22.9 km · 0.9 MW
- Wavehouse 23.7 km · 0.7 MW
- SAP WDF51 24.6 km · 18 MW
- SAP Building 6 / 16 28.9 km · 8 MW
- SAP Building 13 29.1 km · 19 MW
More Pfalzkom data centers
- Pfalzkom DCRN II Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.