Raiffeisen Informatik Technical Services GmbH
Raiffeisen Informatik Technical Services GmbH is an operational data center in Hagenbrunn, Austria. Our footprint estimate of its power is about 5.6 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 5.6 MW (range 2.8 MW to 9 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,676 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Logistikstraße 2, 2201, Hagenbrunn |
| Coordinates | 48.34105, 16.45696 |
| Website | ri-s.at/kontakt |
Power and grid
| Nearest high-voltage substation | Umspannwerk Gerasdorf, 110 kV, 2.5 km away (Wiener Netze) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Bisamberg, 380 kV, 6.1 km away |
| HV substations within 10 km | 6 |
| Power plants within 50 km | 3.3 GW in 28 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 117 g CO₂ per kWh (Austria, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 51.9%, solar 14.1%, gas 11.9%, wind 11.4%, bioenergy 6.3%. Clean power: 83.6% |
| Industrial power price | EUR 0.150 per kWh (Austria, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.9 °C (2001 to 2025) |
| Cooling degree days | 263 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.29 kWh per m² per day |
| Wind at 50 m | 5.9 m/s average |
| Water stress today | Low (<10%) (Austria) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Raiffeisen Informatik Technical Services GmbH use?
We estimate the facility power at about 5.6 MW. Estimate from building footprint, low confidence.
How close is Raiffeisen Informatik Technical Services GmbH to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Gerasdorf (110 kV), about 2.5 km away.
How clean is the power for Raiffeisen Informatik Technical Services GmbH?
The grid in Austria emits about 117 g CO₂ per kWh (2025). Largest sources: hydro 51.9%, solar 14.1%, gas 11.9%.
Data centers near Hagenbrunn
- ODC21 (IBM colocation site) 8.0 km
- A1 Next Generation Datacenter 8.1 km · 4.8 MW
- ATOS Datacenter Siemens City 8.4 km
- AtlasEdge DC Vienna VIE001 8.7 km
- Digital Realty VIE1/2 - Vienna 8.7 km · 36 MW
- AtlasEdge DC Vienna VIE002 8.8 km
- ÖBB Telekom Service Datacenter 9.9 km
- Florido Tower 10.3 km