Digital Realty VIE1/2 - Vienna
Digital Realty VIE1/2 - Vienna is an operational data center operated by Digital Realty in Vienna, Austria. Our footprint estimate of its power is about 36 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 36 MW (range 18 MW to 57 MW) Estimate from building footprint, low confidence. Footprint estimate: about 29,830 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 15,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 192 networks, 13 internet exchanges PeeringDB. |
| Also known as | Digital Realty VIE1 & VIE2 |
| Address | Louis-Haefliger-Gasse 10 |
| Coordinates | 48.26903, 16.41061 |
| Website | digtialrealty.com |
Power and grid
| Nearest high-voltage substation | Umspannwerk Leopoldau, 110 kV, 800 m away (Wien Energie) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Wien Nord, 380 kV, 2 km away |
| HV substations within 10 km | 31 |
| Power plants within 50 km | 3.3 GW in 29 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 117 g CO₂ per kWh (Austria, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 51.9%, solar 14.1%, gas 11.9%, wind 11.4%, bioenergy 6.3%. Clean power: 83.6% |
| Industrial power price | EUR 0.150 per kWh (Austria, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.9 °C (2001 to 2025) |
| Cooling degree days | 263 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.29 kWh per m² per day |
| Wind at 50 m | 5.9 m/s average |
| Water stress today | Low (<10%) (Austria) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty VIE1/2 - Vienna use?
We estimate the facility power at about 36 MW. Estimate from building footprint, low confidence.
How close is Digital Realty VIE1/2 - Vienna to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Leopoldau (110 kV), about 800 m away.
How clean is the power for Digital Realty VIE1/2 - Vienna?
The grid in Austria emits about 117 g CO₂ per kWh (2025). Largest sources: hydro 51.9%, solar 14.1%, gas 11.9%.
Who operates Digital Realty VIE1/2 - Vienna?
Digital Realty.
Data centers near Vienna
- AtlasEdge DC Vienna VIE002 799 m
- AtlasEdge DC Vienna VIE001 847 m
- ATOS Datacenter Siemens City 888 m
- ÖBB Telekom Service Datacenter 1.3 km
- A1 Next Generation Datacenter 1.5 km · 4.8 MW
- Florido Tower 1.6 km
- ODC21 (IBM colocation site) 1.7 km
- Millennium Tower 3.6 km
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States