RIC2 DC2
RIC2 DC2 is an operational data center in Sandston, United States. Our footprint estimate of its power is about 50 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 50 MW (range 25 MW to 81 MW) Estimate from building footprint, low confidence. Footprint estimate: about 42,078 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 21,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | RIC2 DC1 |
| Address | Technology Boulevard 6040, 23150, Sandston |
| Coordinates | 37.48709, -77.24098 |
Power and grid
| Utility | Virginia Electric & Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Virginia Natural Gas Co, intrastate pipeline, 1.5 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 940 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.31 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does RIC2 DC2 use?
We estimate the facility power at about 50 MW. Estimate from building footprint, low confidence.
How clean is the power for RIC2 DC2?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Data centers near Sandston
- QTS Richmond 2 Data Center 253 m · 86 MW
- QTS Richmond (RIC1) 302 m
- RIC1 DC3 350 m
- Meta Research SuperCluster (RSC-1) 459 m · 13 MW
- QTS Richmond 1 606 m · 333 MW
- DC5 762 m · 57 MW
- Meta Henrico Data Center 859 m · 34 MW
- Bank of America Data Center 1.0 km · 38 MW