QTS Richmond 2 Data Center

QTS Richmond 2 Data Center is a data center under construction operated by Quality Technology Services in Sandston, United States. Our footprint estimate of its power is about 86 MW.

Power demand is growing at this site

Key facts

StatusUnder construction
OperatorQuality Technology Services
Facility power86 MW (range 35 MW to 216 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 719,231 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 37,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asRIC2 DC6 · RIC2 DC3 · RIC2 DC5
Coordinates37.48526, -77.24268

Power and grid

Nearest high-voltage substationTechpark Place Substation, 230 kV, 400 m away (Dominion Energy)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km7
UtilityVirginia Electric & Power Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineVirginia Natural Gas Co, intrastate pipeline, 1.7 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.7 GW in 29 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity357 g CO₂ per kWh (Virginia, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39%
Industrial power priceUSD 0.100 per kWh (Virginia, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature14.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.7 °C (2001 to 2025)
Cooling degree days940 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.31 kWh per m² per day
Wind at 50 m4.6 m/s average
Water stress todayMedium - High (20-40%) (Virginia)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does QTS Richmond 2 Data Center use?

We estimate the facility power at about 86 MW. Estimate from building footprint, low confidence.

How close is QTS Richmond 2 Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is Techpark Place Substation (230 kV), about 400 m away. The local utility is Virginia Electric & Power Co, in the PJM balancing area.

How clean is the power for QTS Richmond 2 Data Center?

The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.

Who operates QTS Richmond 2 Data Center?

Quality Technology Services.