Seixal Colocation Site
Seixal Colocation Site is an operational data center operated by TATA Communications in Charneca de Caparica, Portugal. Our footprint estimate of its power is about 2.5 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | TATA Communications |
| Facility power | 2.5 MW (range 1.3 MW to 4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,086 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 38.60000, -9.15986 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 150 kV, 2.4 km away (REN) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Subestação de Fernão Ferro, 400 kV, 4 km away |
| HV substations within 10 km | 7 |
| Power plants within 50 km | 1.7 GW in 43 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 128 g CO₂ per kWh (Portugal, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 29.7%, wind 26.8%, solar 17.3%, gas 16.5%, bioenergy 6.6%. Clean power: 80.9% |
| Industrial power price | EUR 0.090 per kWh (Portugal, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 16.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43.7 °C (2001 to 2025) |
| Cooling degree days | 675 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.87 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | High (40-80%) (Portugal) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Seixal Colocation Site use?
We estimate the facility power at about 2.5 MW. Estimate from building footprint, low confidence.
How close is Seixal Colocation Site to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (150 kV), about 2.4 km away.
How clean is the power for Seixal Colocation Site?
The grid in Portugal emits about 128 g CO₂ per kWh (2025). Largest sources: hydro 29.7%, wind 26.8%, solar 17.3%.
Who operates Seixal Colocation Site?
TATA Communications.
Data centers near Charneca de Caparica
- MEO LDV 15.0 km
- AtlasEdge DC Lisbon LIS001 15.1 km
- NOS Imopolis II 15.2 km · 13 MW
- dotsi - Lisbon DC01 17.3 km
- FCCN Lisbon - SE03 17.4 km
- Equinix LS1 - Lisbon 21.1 km · 4.6 MW
- Altice data center in Rio de Mouro 24.7 km
- Data center in Alhandra 36.7 km · 12 MW
More TATA Communications data centers
- Tata Communications Highbridge Datacentre United Kingdom
- TGN Hillsboro United States
- TATA Communications - Piti Cable Landing Station Guam
- TATA Communications Delhi India
- TATA Communications Kolkata India
- TATA Communications Mumbai India
- TATA Communications Stratford United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.