SFR data center in Saint-Martin-d'Hères
SFR data center in Saint-Martin-d'Hères is an operational data center operated by SFR in Saint-Martin-d'Hères, France. Our footprint estimate of its power is about 2.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | SFR |
| Facility power | 2.9 MW (range 1.4 MW to 4.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,205 m² building outline x 2 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 45.18668, 5.76613 |
Power and grid
| Nearest high-voltage substation | Poste électrique de Eybens, 225 kV, 3.8 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 4 |
| Power plants within 50 km | 833 MW in 39 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 2.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 27.4 °C (2001 to 2025) |
| Cooling degree days | 1 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.72 kWh per m² per day |
| Wind at 50 m | 2.8 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does SFR data center in Saint-Martin-d'Hères use?
We estimate the facility power at about 2.9 MW. Estimate from building footprint, low confidence.
How close is SFR data center in Saint-Martin-d'Hères to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique de Eybens (225 kV), about 3.8 km away.
How clean is the power for SFR data center in Saint-Martin-d'Hères?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates SFR data center in Saint-Martin-d'Hères?
SFR.
Data centers near Saint-Martin-d'Hères
- Bouygues Télécom data center in Saint-Martin-d'Hères 83 m · 0.9 MW
- Cogent Grenoble 2.3 km
- Data center in Eybens 4.0 km · 7.7 MW
- Orange Business - La Fabrique [Grenoble] 4.5 km · 3 MW
- dc2scale ALP1 (Grenoble) 4.8 km
- UltraEdge Grenoble 5.1 km
- XSALTO Grenoble 6.4 km
- Data center in Voreppe 18.9 km
More SFR data centers
- Le Prologue France
- SFR Netcenter Bordeaux France
- Site technique SFR France
- Site technique SFR France
- SFR France
- Site technique SFR France
- SFR data center in Saint-Herblain France
- SFR data center in Montpellier France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.