SSE data center in Havant

SSE data center in Havant is an operational data center operated by SSE in Havant, United Kingdom. Our footprint estimate of its power is about 1.8 MW.

Key facts

StatusOperational
OperatorSSE
Facility power1.8 MW (range 0.9 MW to 2.9 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,532 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 770 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressMartin Road, PO9 5TH, Havant
Coordinates50.86642, -0.97568

Power and grid

Nearest high-voltage substationHavant Substation, 132 kV, 2.7 km away (Scottish and Southern Electricity Networks)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationLovedean Substation, 400 kV, 7.2 km away
HV substations within 10 km6
Power plants within 50 km2.1 GW in 92 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity218 g CO₂ per kWh (United Kingdom, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2%

Climate and water

Average temperature10.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature33.7 °C (2001 to 2025)
Cooling degree days48 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.94 kWh per m² per day
Wind at 50 m7.4 m/s average
Water stress todayLow - Medium (10-20%) (England)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does SSE data center in Havant use?

We estimate the facility power at about 1.8 MW. Estimate from building footprint, low confidence.

How close is SSE data center in Havant to the power grid?

The nearest high-voltage substation in OpenStreetMap is Havant Substation (132 kV), about 2.7 km away.

How clean is the power for SSE data center in Havant?

The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.

Who operates SSE data center in Havant?

SSE.