STACK MILL1B
STACK MILL1B is an operational data center operated by STACK in Siziano, Italy. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | STACK |
| Facility power | 12 MW (range 6 MW to 19 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,945 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 45.33122, 9.20381 |
Power and grid
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
|---|---|
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.2 °C (2001 to 2025) |
| Cooling degree days | 482 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.78 kWh per m² per day |
| Wind at 50 m | 3 m/s average |
| Water stress today | High (40-80%) (Italy) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does STACK MILL1B use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How clean is the power for STACK MILL1B?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates STACK MILL1B?
STACK.
Data centers near Siziano
- Vaultica Data Centers | MIL01 172 m · 12 MW
- Data center in Siziano 202 m
- STACK MILL2 296 m · 8.4 MW
- Equinix ML3 - Milan, Basiglio 5.1 km · 2.1 MW
- Data center in Melegnano 8.7 km · 13 MW
- Noviglio Datacenter Mxp 9.1 km · 27 MW
- Data center in San Donato Milanese 10.9 km
- Equinix ML2 - Milan, Savona 13.8 km
More STACK data centers
- STACK MILL2 Italy
- Stack.HTH Russia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.