Equinix ML3 - Milan, Basiglio
Equinix ML3 - Milan, Basiglio is an operational data center operated by Equinix in Milan, Italy. Our footprint estimate of its power is about 2.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Facility power | 2.1 MW (range 1 MW to 3.3 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,720 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks, 1 internet exchanges PeeringDB. |
| Also known as | Equinix Milan ML3 |
| Address | Via Francesco Sforza 13, Basiglio |
| Coordinates | 45.35407, 9.14732 |
| Website | equinix.com/locations/europe-colocation/italy-colocation/milan-data-centers/ml3 |
Power and grid
| Nearest high-voltage substation | Lacchiarella CP, 132 kV, 1.5 km away (Enel Distribuzione) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Lacchiarella, 380 kV, 1.6 km away |
| HV substations within 10 km | 16 |
| Power plants within 50 km | 7.9 GW in 22 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.2 °C (2001 to 2025) |
| Cooling degree days | 482 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.78 kWh per m² per day |
| Wind at 50 m | 3 m/s average |
| Water stress today | High (40-80%) (Italy) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Equinix ML3 - Milan, Basiglio use?
We estimate the facility power at about 2.1 MW. Estimate from building footprint, low confidence.
How close is Equinix ML3 - Milan, Basiglio to the power grid?
The nearest high-voltage substation in OpenStreetMap is Lacchiarella CP (132 kV), about 1.5 km away.
How clean is the power for Equinix ML3 - Milan, Basiglio?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates Equinix ML3 - Milan, Basiglio?
Equinix.
Data centers near Milan
- Data center in Siziano 4.9 km
- Noviglio Datacenter Mxp 5.0 km · 27 MW
- STACK MILL1B 5.1 km · 12 MW
- STACK MILL2 5.2 km · 8.4 MW
- Vaultica Data Centers | MIL01 5.2 km · 12 MW
- Equinix ML2 - Milan, Savona 10.5 km
- Retelit Avalon 3 10.7 km · 6.7 MW
- Keppel Data Centres | Milan Data Centre 11.3 km
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.