TRG Datacenters Houston (HOU1) (HOU2)
TRG Datacenters Houston (HOU1) (HOU2) is an operational data center operated by TRG Datacenters in Spring, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | TRG Datacenters |
| Networks | 18 networks, 4 internet exchanges PeeringDB. |
| Address | 2626 Spring Cypress Road |
| Coordinates | 30.06599, -95.45902 |
| Website | trgdatacenters.com/infrastructure/houston-data-center |
Power and grid
| Nearest high-voltage substation | Springwood Substation, 138 kV, 2.9 km away (CenterPoint Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Rothwood Substation, 345 kV, 4 km away |
| HV substations within 10 km | 7 |
| Utility | San Bernard Electric Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | Tennessee Gas Pipeline, interstate pipeline, 4.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 9.8 GW in 27 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.7 °C (2001 to 2025) |
| Cooling degree days | 1,754 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.65 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is TRG Datacenters Houston (HOU1) (HOU2) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Springwood Substation (138 kV), about 2.9 km away. The local utility is San Bernard Electric Coop, INC, in the ERCO balancing area.
How clean is the power for TRG Datacenters Houston (HOU1) (HOU2)?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates TRG Datacenters Houston (HOU1) (HOU2)?
TRG Datacenters.
Data centers near Spring
- ExxonMobil Discovery 6 4.3 km · 5.7 MW
- Stream Data Centers - Houston I 12.7 km · 22 MW
- DXC Technology data center in Cypress 12.8 km · 33 MW
- Data Foundry Houston 2 13.8 km · 10 MW
- Cogent Houston 14.2 km
- Digital Realty HOU (12001 North Freeway) 14.2 km
- Equinix HO1 - Houston 17.1 km
- Databank Houston West (HOU1) (HOU2) 26.4 km