Equinix HO1 - Houston
Equinix HO1 - Houston is an operational data center operated by Equinix in Houston, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Equinix |
| Networks | 4 networks, 1 internet exchanges PeeringDB. |
| Address | 1515 Aldine Meadows Road |
| Coordinates | 29.93580, -95.36435 |
| Website | equinix.com/locations/united-states-colocation/houston-data-centers/ho1 |
Power and grid
| Nearest high-voltage substation | North Belt Substation, 345 kV, 700 m away (CenterPoint Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 13 |
| Utility | San Bernard Electric Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | Houston Pipeline Co, intrastate pipeline, 1.1 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 14 GW in 36 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.7 °C (2001 to 2025) |
| Cooling degree days | 1,754 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.65 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Equinix HO1 - Houston to the power grid?
The nearest high-voltage substation in OpenStreetMap is North Belt Substation (345 kV), about 700 m away. The local utility is San Bernard Electric Coop, INC, in the ERCO balancing area.
How clean is the power for Equinix HO1 - Houston?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Equinix HO1 - Houston?
Equinix.
Data centers near Houston
- Cogent Houston 5.1 km
- Digital Realty HOU (12001 North Freeway) 5.1 km
- Data Foundry Houston 2 5.9 km · 10 MW
- TRG Datacenters Houston (HOU1) (HOU2) 17.1 km
- Quasar Data Center 19.5 km
- Alpheus Houston (777 Walker Street) 19.6 km
- InterConnX Realty 20.2 km
- ExxonMobil Discovery 6 20.2 km · 5.7 MW
More Equinix data centers
- Equinix DA1 - Dallas United States
- Equinix SP6 Brazil
- Equinix PH1 - Philadelphia United States
- Equinix PA13X France
- Equinix CH1/CH2/CH4 - Chicago United States
- Equinix CH3 - Elk Grove United States
- Equinix AM3 - Amsterdam, Science Park Netherlands
- Equinix LA1 - Los Angeles United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.