University Corporation for Atmospheric Research data center in Cheyenne

University Corporation for Atmospheric Research data center in Cheyenne is an operational data center operated by University Corporation for Atmospheric Research in Cheyenne, United States. Our footprint estimate of its power is about 6.4 MW.

Key facts

StatusOperational
OperatorUniversity Corporation for Atmospheric Research
Facility power6.4 MW (range 2.6 MW to 16 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 53,381 m² site outline x 0.12 kW per m² of land.
GPU capacity if all AIabout 2,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asNCAR-Wyoming Supercomputing Center
Coordinates41.12856, -104.89688
Websitenwsc.ucar.edu/visitor-center

Power and grid

Nearest high-voltage substationMicrosoft/Data Center Substation, 115 kV, 600 m away (Cheyenne Light Fuel and Power)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationCheyenne Substation, 230 kV, 7.3 km away
HV substations within 10 km14
UtilityCheyenne Light Fuel & Power (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityWACM
Nearest gas pipelineWyoming Interstate PL Co, interstate pipeline, 5.8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km1.1 GW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity620 g CO₂ per kWh (Wyoming, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 58.5%, wind 27.1%, gas 10%, hydro 2.1%, solar 1.2%. Clean power: 30.4%
Industrial power priceUSD 0.088 per kWh (Wyoming, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature8.2 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.4 °C (2001 to 2025)
Cooling degree days304 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.57 kWh per m² per day
Wind at 50 m7.1 m/s average
Water stress todayHigh (40-80%) (Wyoming)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does University Corporation for Atmospheric Research data center in Cheyenne use?

We estimate the facility power at about 6.4 MW. Estimate from building footprint, low confidence.

How close is University Corporation for Atmospheric Research data center in Cheyenne to the power grid?

The nearest high-voltage substation in OpenStreetMap is Microsoft/Data Center Substation (115 kV), about 600 m away. The local utility is Cheyenne Light Fuel & Power, in the WACM balancing area.

How clean is the power for University Corporation for Atmospheric Research data center in Cheyenne?

The grid in Wyoming emits about 620 g CO₂ per kWh (2025). Largest sources: coal 58.5%, wind 27.1%, gas 10%.

Who operates University Corporation for Atmospheric Research data center in Cheyenne?

University Corporation for Atmospheric Research.