Vantage data center in Santa Clara
Vantage data center in Santa Clara is an operational data center operated by Vantage in Santa Clara, United States. Our footprint estimate of its power is about 9.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Vantage |
| Facility power | 9.8 MW (range 4.9 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,127 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 37.37331, -121.97278 |
Power and grid
| Nearest high-voltage substation | Scott Receiving Station, 115 kV, 1.7 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Northern Receiving Station, 230 kV, 3.2 km away |
| HV substations within 10 km | 30 |
| Utility | City Of Santa Clara (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 1.5 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.1 GW in 26 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 14 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 370 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.32 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Vantage data center in Santa Clara use?
We estimate the facility power at about 9.8 MW. Estimate from building footprint, low confidence.
How close is Vantage data center in Santa Clara to the power grid?
The nearest high-voltage substation in OpenStreetMap is Scott Receiving Station (115 kV), about 1.7 km away. The local utility is City Of Santa Clara, in the CISO balancing area.
How clean is the power for Vantage data center in Santa Clara?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates Vantage data center in Santa Clara?
Vantage.
Data centers near Santa Clara
- Digital Realty SJC (2820 NW Pkwy) 76 m · 12 MW
- CoreSite - Santa Clara (SV3) 289 m · 5.2 MW
- CoreSite - Santa Clara (SV7) 311 m · 5.3 MW
- Data center in Santa Clara 332 m · 18 MW
- Centersquare Silicon Valley (SFO1) 336 m · 10 MW
- CoreSite - Santa Clara (SV4) 376 m · 4.4 MW
- Csquare SFO1 411 m · 9 MW
- CoreSite - Santa Clara (SV8) 463 m · 3.9 MW
More Vantage data centers
- Vantage Building 3 United States
- Vantage OH1 Data Center Campus United States
- Vantage Quincy Campus United States