VIRTUS London 11
VIRTUS London 11 is an operational data center in Slough, United Kingdom. Our footprint estimate of its power is about 7.2 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 7.2 MW (range 3.6 MW to 12 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,037 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | SL1 4EQ, Slough |
| Coordinates | 51.51896, -0.62625 |
| Website | virtusdatacentres.com/locations/uk/london/slough-london11 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 132 kV, 500 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Iver Substation, 400 kV, 9.3 km away |
| HV substations within 10 km | 12 |
| Power plants within 50 km | 3.8 GW in 96 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.9 °C (2001 to 2025) |
| Cooling degree days | 53 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.94 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does VIRTUS London 11 use?
We estimate the facility power at about 7.2 MW. Estimate from building footprint, low confidence.
How close is VIRTUS London 11 to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (132 kV), about 500 m away.
How clean is the power for VIRTUS London 11?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Data centers near Slough
- China Mobile International - London DC 187 m · 7.5 MW
- CyrusOne London 4 260 m · 22 MW
- Iron Mountain LON-2 368 m · 12 MW
- Equinix LD10 - London, Slough 385 m · 2.9 MW
- Equinix LD5 - London, Slough 435 m · 21 MW
- Digital Realty London LHR27 440 m
- CyrusOne London 1 482 m · 8.6 MW
- VIRTUS LONDON9 502 m · 34 MW
Sources