AirTrunk SGP1
AirTrunk SGP1 is an operational data center operated by AirTrunk Operating in Singapore, Singapore. Our footprint estimate of its power is about 2.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | AirTrunk Operating |
| Facility power | 2.6 MW (range 1.1 MW to 6.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 22,058 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 1,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks PeeringDB. |
| Address | 22 Loyang Drive |
| Coordinates | 1.37714, 103.96750 |
| Website | airtrunk.com |
Power and grid
| Nearest high-voltage substation | Tampines Wafer Substation 230kV, 230 kV, 4.7 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 2 |
| Power plants within 50 km | 19 GW in 38 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 497 g CO₂ per kWh (Singapore, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 91.1%, bioenergy 2.8%, solar 2.7%, oil and other fossil 2.5%, coal 0.9%. Clean power: 5.5% |
Climate and water
| Average temperature | 27.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 33.9 °C (2001 to 2025) |
| Cooling degree days | 3,296 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.82 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | NoData (Singapore) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does AirTrunk SGP1 use?
We estimate the facility power at about 2.6 MW. Estimate from building footprint, low confidence.
How close is AirTrunk SGP1 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Tampines Wafer Substation 230kV (230 kV), about 4.7 km away.
How clean is the power for AirTrunk SGP1?
The grid in Singapore emits about 497 g CO₂ per kWh (2025). Largest sources: gas 91.1%, bioenergy 2.8%, solar 2.7%.
Who operates AirTrunk SGP1?
AirTrunk Operating.
Data centers near Singapore
- AirTrunk Singapore SGP1 97 m · 90 MW
- Amazon Web Services data center in Loyang 308 m · 2 MW
- Starhub Data Center @ Loyang 376 m
- Digital Realty Singapore SIN12 599 m
- STTGDC SIN6 628 m · 1.8 MW
- Digital Realty Singapore SIN11 696 m · 75 MW
- OCBC data center in Singapore 769 m · 28 MW
- Telin-1 2.8 km · 6.8 MW
More AirTrunk Operating data centers
- AirTrunk SYD1 Australia
- AirTrunk MEL1 Australia
- AirTrunk HKG1 Hong Kong SAR China
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.