ATI Solutions
ATI Solutions is an operational data center operated by ATI Solutions in Chantilly, United States. Our footprint estimate of its power is about 3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | ATI Solutions |
| Facility power | 3 MW (range 1.5 MW to 4.8 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,507 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks PeeringDB. |
| Address | 4227 Lafayette Center Drive |
| Coordinates | 38.90814, -77.47526 |
| Website | atisolutions.com |
Power and grid
| Utility | Virginia Electric & Power Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Columbia Gas Trans Co, interstate pipeline, 3.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 357 g CO₂ per kWh (Virginia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 56.7%, nuclear 26.4%, solar 9.5%, coal 3.4%, bioenergy 3.3%. Clean power: 39% |
| Industrial power price | USD 0.100 per kWh (Virginia, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.7 °C (2001 to 2025) |
| Cooling degree days | 729 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.98 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (Virginia) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does ATI Solutions use?
We estimate the facility power at about 3 MW. Estimate from building footprint, low confidence.
How clean is the power for ATI Solutions?
The grid in Virginia emits about 357 g CO₂ per kWh (2025). Largest sources: gas 56.7%, nuclear 26.4%, solar 9.5%.
Who operates ATI Solutions?
ATI Solutions.
Data centers near Chantilly
- H5 Data Centers Virginia (4030) 324 m · 20 MW
- 4120 Lafayette Center Drive 593 m · 4.7 MW
- Amazon IAD-150 899 m · 63 MW
- Data center in South Riding 1.6 km · 13 MW
- Amazon IAD-61 1.7 km · 32 MW
- Amazon IAD-156 1.7 km · 14 MW
- Amazon IAD-135 1.8 km · 21 MW
- Amazon IAD-86 2.0 km · 16 MW