Banque de France data center in Lagny-sur-Marne
Banque de France data center in Lagny-sur-Marne is an operational data center operated by Banque de France in Lagny-sur-Marne, France. Our footprint estimate of its power is about 9.1 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Banque de France |
| Facility power | 9.1 MW (range 3.6 MW to 23 MW) Estimate from building footprint, low confidence. Footprint estimate: about 75,641 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 3,900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | Datacenter Banque de France |
| Coordinates | 48.83863, 2.78832 |
Power and grid
| Nearest high-voltage substation | Poste électrique d’Orsonville, 225 kV, 1.7 km away (RTE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 5 |
| Power plants within 50 km | 1.9 GW in 46 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.3 °C (2001 to 2025) |
| Cooling degree days | 122 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.19 kWh per m² per day |
| Wind at 50 m | 6.2 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Banque de France data center in Lagny-sur-Marne use?
We estimate the facility power at about 9.1 MW. Estimate from building footprint, low confidence.
How close is Banque de France data center in Lagny-sur-Marne to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste électrique d’Orsonville (225 kV), about 1.7 km away.
How clean is the power for Banque de France data center in Lagny-sur-Marne?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Banque de France data center in Lagny-sur-Marne?
Banque de France.
Data centers near Lagny-sur-Marne
- BNP Paribas (Hello Bank!) 1.1 km · 2.1 MW
- Datacenter Vega 1.3 km · 20 MW
- Euroclear 4.3 km · 7.4 MW
- BNP Paribas Centre de Traitement Informatique (CTI) Marne Nord 4.4 km · 18 MW
- Digital Realty Paris PAR12 5.1 km · 16 MW
- Datacenter IBM 7.0 km · 1.1 MW
- Datacenter IBM 8.5 km · 4.1 MW
- Penta Infra Paris PAR01 10.8 km · 5.1 MW
More Banque de France data centers
- Datacenter Banque de France France
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.