Digital Realty Paris PAR12
Digital Realty Paris PAR12 is an operational data center operated by Digital Realty in Ferrières-en-Brie, France. Our footprint estimate of its power is about 16 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 16 MW (range 7.9 MW to 25 MW) Estimate from building footprint, low confidence. Footprint estimate: about 13,094 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 6,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 1 networks PeeringDB. |
| Also known as | Digital Realty PAR12 |
| Address | 16 Avenue Joseph Froelicher |
| Coordinates | 48.82327, 2.72220 |
| Website | digitalrealty.fr/data-centers/emea/paris/par12 |
Power and grid
| Nearest high-voltage substation | Poste source de Génitoy, 225 kV, 1.3 km away (Enedis) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 8 |
| Power plants within 50 km | 1.9 GW in 47 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 41 g CO₂ per kWh (France, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 68.3%, hydro 10.3%, wind 8.8%, solar 5.6%, gas 3%. Clean power: 94.9% |
| Industrial power price | EUR 0.098 per kWh (France, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.6 °C (2001 to 2025) |
| Cooling degree days | 130 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.19 kWh per m² per day |
| Wind at 50 m | 6.3 m/s average |
| Water stress today | Low - Medium (10-20%) (France) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty Paris PAR12 use?
We estimate the facility power at about 16 MW. Estimate from building footprint, low confidence.
How close is Digital Realty Paris PAR12 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Poste source de Génitoy (225 kV), about 1.3 km away.
How clean is the power for Digital Realty Paris PAR12?
The grid in France emits about 41 g CO₂ per kWh (2025). Largest sources: nuclear 68.3%, hydro 10.3%, wind 8.8%.
Who operates Digital Realty Paris PAR12?
Digital Realty.
Data centers near Ferrières-en-Brie
- BNP Paribas Centre de Traitement Informatique (CTI) Marne Nord 943 m · 18 MW
- Euroclear 1.1 km · 7.4 MW
- Datacenter IBM 2.4 km · 1.1 MW
- Datacenter IBM 3.7 km · 4.1 MW
- Banque de France data center in Lagny-sur-Marne 5.1 km · 9.1 MW
- APPLIWAVE - CBO 5.9 km
- BNP Paribas Marne Sud 5.9 km · 6 MW
- BNP Paribas (Hello Bank!) 6.1 km · 2.1 MW
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.