Centro de datos Triara Querétaro

Centro de datos Triara Querétaro is an operational data center operated by Triara in Santiago de Querétaro, Mexico. Our footprint estimate of its power is about 18 MW.

Key facts

StatusOperational
OperatorTriara
Facility power18 MW (range 9.2 MW to 30 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 15,365 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates20.61152, -100.39422

Power and grid

Nearest high-voltage substationSubestación Oriente, 115 kV, 2 km away (CFE)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationQueretaro 1, 230 kV, 5.8 km away
HV substations within 10 km25
Power plants within 50 km730 MW in 2 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity481 g CO₂ per kWh (Mexico, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 70%, hydro 7.5%, solar 7%, wind 5.6%, coal 3.3%. Clean power: 24.2%

Climate and water

Average temperature17.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature36.2 °C (2001 to 2025)
Cooling degree days416 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.89 kWh per m² per day
Wind at 50 m4.7 m/s average
Water stress todayHigh (40-80%) (Mexico)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Centro de datos Triara Querétaro use?

We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.

How close is Centro de datos Triara Querétaro to the power grid?

The nearest high-voltage substation in OpenStreetMap is Subestación Oriente (115 kV), about 2 km away.

How clean is the power for Centro de datos Triara Querétaro?

The grid in Mexico emits about 481 g CO₂ per kWh (2025). Largest sources: gas 70%, hydro 7.5%, solar 7%.

Who operates Centro de datos Triara Querétaro?

Triara.

Data centers near Santiago de Querétaro

More Triara data centers