Centro de datos Triara Querétaro
Centro de datos Triara Querétaro is an operational data center operated by Triara in Santiago de Querétaro, Mexico. Our footprint estimate of its power is about 18 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Triara |
| Facility power | 18 MW (range 9.2 MW to 30 MW) Estimate from building footprint, low confidence. Footprint estimate: about 15,365 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 20.61152, -100.39422 |
Power and grid
| Nearest high-voltage substation | Subestación Oriente, 115 kV, 2 km away (CFE) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Queretaro 1, 230 kV, 5.8 km away |
| HV substations within 10 km | 25 |
| Power plants within 50 km | 730 MW in 2 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 481 g CO₂ per kWh (Mexico, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 70%, hydro 7.5%, solar 7%, wind 5.6%, coal 3.3%. Clean power: 24.2% |
Climate and water
| Average temperature | 17.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 36.2 °C (2001 to 2025) |
| Cooling degree days | 416 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.89 kWh per m² per day |
| Wind at 50 m | 4.7 m/s average |
| Water stress today | High (40-80%) (Mexico) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Centro de datos Triara Querétaro use?
We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.
How close is Centro de datos Triara Querétaro to the power grid?
The nearest high-voltage substation in OpenStreetMap is Subestación Oriente (115 kV), about 2 km away.
How clean is the power for Centro de datos Triara Querétaro?
The grid in Mexico emits about 481 g CO₂ per kWh (2025). Largest sources: gas 70%, hydro 7.5%, solar 7%.
Who operates Centro de datos Triara Querétaro?
Triara.
Data centers near Santiago de Querétaro
- EdgeUno Datacenter Mexico (QRO2) 111 m
- EdgeUno Datacenter Queretaro Mexico (QRO2) 171 m
- Ascenty QRO02 - Querétaro 3.7 km
- RedIT Queretaro 6.7 km
- Equinix MX1/MX2 - Mexico City 13.6 km · 2.6 MW
- Alibaba Cloud in Mexico 14.3 km
- Centro de datos KIO QRO1 y QRO2 15.2 km · 3.4 MW
- KIO Querétaro 1 (QRO1) 15.4 km