Data 4 MAD2 Campus
Data 4 MAD2 Campus is an operational data center operated by Data4 in San Agustín del Guadalix, Spain. Our footprint estimate of its power is about 6.7 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Data4 |
| Facility power | 6.7 MW (range 2.7 MW to 17 MW) Estimate from building footprint, low confidence. Footprint estimate: about 56,162 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 2,900 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Also known as | DATA4 - MAD2-DC01 · DATA4 MAD2-DC02 |
| Address | Calle Begoña Villacís, San Agustín del Guadalix |
| Coordinates | 40.67064, -3.60783 |
| Website | data4group.com/en/data-center-in-madrid-spain-2 |
Power and grid
| Nearest high-voltage substation | Subestación Algete, 220 kV, 9.8 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 1 |
| Power plants within 50 km | 105 MW in 3 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 154 g CO₂ per kWh (Spain, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 21.9%, gas 21.5%, wind 20.4%, nuclear 18.8%, hydro 11.4%. Clean power: 74.6% |
| Industrial power price | EUR 0.105 per kWh (Spain, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.9 °C (2001 to 2025) |
| Cooling degree days | 623 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.7 kWh per m² per day |
| Wind at 50 m | 5.1 m/s average |
| Water stress today | High (40-80%) (Spain) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data 4 MAD2 Campus use?
We estimate the facility power at about 6.7 MW. Estimate from building footprint, low confidence.
How close is Data 4 MAD2 Campus to the power grid?
The nearest high-voltage substation in OpenStreetMap is Subestación Algete (220 kV), about 9.8 km away.
How clean is the power for Data 4 MAD2 Campus?
The grid in Spain emits about 154 g CO₂ per kWh (2025). Largest sources: solar 21.9%, gas 21.5%, wind 20.4%.
Who operates Data 4 MAD2 Campus?
Data4.
Data centers near San Agustín del Guadalix
- Microsoft MAD01 9.9 km · 10 MW
- Cogent Madrid 11.7 km
- Microsoft MAD02 13.5 km · 7.6 MW
- Equinix MD2 - Madrid 15.3 km
- DATA4 Madrid-Alcobendas - MAD1 15.5 km
- DATA4 - MAD1 15.6 km · 6 MW
- CyrusOne Madrid 1 15.6 km
- Equinix MD6 15.9 km · 3 MW
More Data4 data centers
- Data4 Campus Paris Saclay France
- Data4 Campus Nozay PAR3 France
- data4 data center in Marcoussis France
- DATA4 - MAD1 Spain
- data4 data center in Marcoussis France
- DATA4 Paris Marcoussis PAR2 France
- Data4 Pologne WAW2 Poland