Data center in Carteret
Data center in Carteret is an operational data center in Carteret, United States. Our footprint estimate of its power is about 23 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 23 MW (range 12 MW to 37 MW) Estimate from building footprint, low confidence. Footprint estimate: about 19,319 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 9,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Federal Boulevard 1400, 07008, Carteret |
| Coordinates | 40.58437, -74.24338 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 230 kV, 900 m away (Public Service Enterprise Group) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 21 |
| Utility | Public Service Elec & Gas Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 300 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 18 GW in 166 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 265 g CO₂ per kWh (New Jersey, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.8%, nuclear 43.2%, solar 9%, oil and other fossil 1.5%, bioenergy 0.9%. Clean power: 52.8% |
| Industrial power price | USD 0.162 per kWh (New Jersey, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.3 °C (2001 to 2025) |
| Cooling degree days | 481 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.01 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Medium - High (20-40%) (New Jersey) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Carteret use?
We estimate the facility power at about 23 MW. Estimate from building footprint, low confidence.
How close is Data center in Carteret to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (230 kV), about 900 m away. The local utility is Public Service Elec & Gas Co, in the PJM balancing area.
How clean is the power for Data center in Carteret?
The grid in New Jersey emits about 265 g CO₂ per kWh (2025). Largest sources: gas 45.8%, nuclear 43.2%, solar 9%.
Data centers near Carteret
- Metanet New York Data Center Staten Island 5.7 km
- Telehouse Teleport 6.3 km · 11 MW
- Telehouse - Teleport Center (New York) 6.4 km
- Merrill Lynch Data Center 6.5 km · 8.5 MW
- Barclays Datacenter 7.5 km · 14 MW
- Iron Mountain Data Center - New Jersey (NJE-1) 11.3 km · 138 MW
- Equinix NY1 - New York, Newark 18.0 km · 12 MW
- Centersquare New Jersey (EWR3) 18.3 km