Data center in Pleasant Hill
Data center in Pleasant Hill is an operational data center in Pleasant Hill, United States. Our footprint estimate of its power is about 2.3 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 2.3 MW (range 1.2 MW to 3.7 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,952 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 980 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 41.55815, -93.52822 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 345 kV, 300 m away (MidAmerican Energy) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 12 |
| Utility | Midamerican Energy Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | MISO |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 500 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 1.1 GW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 313 g CO₂ per kWh (Iowa, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 58.5%, coal 25.6%, gas 11.6%, solar 2.5%, hydro 1.4%. Clean power: 62.8% |
| Industrial power price | USD 0.093 per kWh (Iowa, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 10.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.6 °C (2001 to 2025) |
| Cooling degree days | 586 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.09 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low - Medium (10-20%) (Iowa) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Pleasant Hill use?
We estimate the facility power at about 2.3 MW. Estimate from building footprint, low confidence.
How close is Data center in Pleasant Hill to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (345 kV), about 300 m away. The local utility is Midamerican Energy Co, in the MISO balancing area.
How clean is the power for Data center in Pleasant Hill?
The grid in Iowa emits about 313 g CO₂ per kWh (2025). Largest sources: wind 58.5%, coal 25.6%, gas 11.6%.
Data centers near Pleasant Hill
- Microsoft GPT-4 cluster 8.5 km · 21 MW
- Connect Des Moines 8.6 km
- Aureon Downtown 9.2 km · 2.7 MW
- Facebook Altoona Data Center 1 11.9 km · 49 MW
- Facebook Altoona Data Center 4 12.2 km · 102 MW
- Facebook Altoona Data Center 3 12.2 km · 109 MW
- Altoona Meta Data Center 12.6 km · 306 MW
- Facebook Altoona Data Center 5 12.6 km · 69 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.