Data center in Sannazzaro de' Burgondi
Data center in Sannazzaro de' Burgondi is an operational data center in Sannazzaro de' Burgondi, Italy. Our footprint estimate of its power is about 29 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 29 MW (range 14 MW to 46 MW) Estimate from building footprint, low confidence. Footprint estimate: about 23,881 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 12,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 45.09925, 8.86088 |
Power and grid
| Nearest high-voltage substation | Ferrera Erbognone, 380 kV, 300 m away (Enipower) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 8 |
| Power plants within 50 km | 4.1 GW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.8 °C (2001 to 2025) |
| Cooling degree days | 633 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.78 kWh per m² per day |
| Wind at 50 m | 3.5 m/s average |
| Water stress today | High (40-80%) (Italy) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Sannazzaro de' Burgondi use?
We estimate the facility power at about 29 MW. Estimate from building footprint, low confidence.
How close is Data center in Sannazzaro de' Burgondi to the power grid?
The nearest high-voltage substation in OpenStreetMap is Ferrera Erbognone (380 kV), about 300 m away.
How clean is the power for Data center in Sannazzaro de' Burgondi?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Data centers near Sannazzaro de' Burgondi
- Eni HPC6 225 m · 14 MW
- TIM data center in Voghera 16.4 km
- Noviglio Datacenter Mxp 31.8 km · 27 MW
- Equinix ML3 - Milan, Basiglio 36.1 km · 2.1 MW
- STACK MILL2 37.0 km · 8.4 MW
- Data center in Siziano 37.1 km
- STACK MILL1B 37.2 km · 12 MW
- Vaultica Data Centers | MIL01 37.4 km · 12 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.