Data Center Directory

Data center in Sannazzaro de' Burgondi

Data center in Sannazzaro de' Burgondi is an operational data center in Sannazzaro de' Burgondi, Italy. Our footprint estimate of its power is about 29 MW.

Key facts

StatusOperational
Facility power29 MW (range 14 MW to 46 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 23,881 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 12,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Coordinates45.09925, 8.86088

Power and grid

Nearest high-voltage substationFerrera Erbognone, 380 kV, 300 m away (Enipower)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km8
Power plants within 50 km4.1 GW in 9 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity285 g CO₂ per kWh (Italy, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7%
Industrial power priceEUR 0.173 per kWh (Italy, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature13.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.8 °C (2001 to 2025)
Cooling degree days633 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.78 kWh per m² per day
Wind at 50 m3.5 m/s average
Water stress todayHigh (40-80%) (Italy)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Data center in Sannazzaro de' Burgondi use?

We estimate the facility power at about 29 MW. Estimate from building footprint, low confidence.

How close is Data center in Sannazzaro de' Burgondi to the power grid?

The nearest high-voltage substation in OpenStreetMap is Ferrera Erbognone (380 kV), about 300 m away.

How clean is the power for Data center in Sannazzaro de' Burgondi?

The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.

Data centers near Sannazzaro de' Burgondi

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.