Data Foundry Texas 1
Data Foundry Texas 1 is an operational data center operated by Data Foundry in Austin, United States. Our footprint estimate of its power is about 27 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Data Foundry |
| Facility power | 27 MW (range 13 MW to 43 MW) Estimate from building footprint, low confidence. Footprint estimate: about 22,250 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 12,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 15 networks, 1 internet exchanges PeeringDB. |
| Also known as | Data Foundry - Texas 1 · Data Foundry - Texas 2 |
| Address | 4100 Smith School Road |
| Coordinates | 30.19893, -97.71372 |
| Website | datafoundry.com |
Power and grid
| Utility | Austin Energy (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Kinder Morgan Texas Pipeline Co, intrastate pipeline, 0 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 20.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.6 °C (2001 to 2025) |
| Cooling degree days | 1,858 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.81 kWh per m² per day |
| Wind at 50 m | 6.1 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data Foundry Texas 1 use?
We estimate the facility power at about 27 MW. Estimate from building footprint, low confidence.
How clean is the power for Data Foundry Texas 1?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Data Foundry Texas 1?
Data Foundry.
Data centers near Austin
- Lumen Austin 1 298 m · 22 MW
- LightEdge Austin 2 (AUS2) 729 m · 18 MW
- CyrusOne Austin (Met 3) 1.5 km · 6 MW
- CyrusOne Austin (Met 2) 1.7 km · 2.7 MW
- LightEdge Austin 1 (AUS1) 1.7 km · 5.3 MW
- Cogent Austin 1.9 km
- Digital Realty AUS11 - Austin 2.3 km · 19 MW
- Data Foundry Austin 1 2.6 km · 9.1 MW
More Data Foundry data centers
- Data Foundry Houston 2 United States
- Data Foundry Austin 1 United States
- Data Foundry Houston 1 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.